HISTORICAL SENSOR DATA

Sensor Data Report

DB LIVE
CURRENT TIME--:--:--
GuestVIEW ONLY
DEVICE NETWORK Gateway Status
11 gateway ditampilkan · realtime ~1s · history 60s
Weather WS-MOD-01
ONLINE
Actuator ACT-MOD-01
ONLINE
Mainboard L3 MB-L3-01
ONLINE
Mainboard L5 MB-L5-01
ONLINE
Remote AC AC-REMOTE-01
ONLINE
Sensor Mainboard L3 PWR-L3-01
ONLINE
Sensor Lampu L3 PWR-L3-02
ONLINE
Sensor Mainboard L5 PWR-L5-01
ONLINE
Sensor Lampu L5 PWR-L5-02
ONLINE
Sensor Actuator L5 PWR-L5-03
ONLINE
Sensor Pendingin Ruangan PWR-L5-04
ONLINE
REPORT FILTER

Periode & Sensor

DATABASE HISTORY
RESET
QUICK RANGE Hari ini 7 hari 30 hari
PERIODE19 Oct 2026sampai 19 Oct 2026
TOTAL DATA163,616sensor readings
MINIMUM-36.11sesuai filter
AVERAGE89.08sesuai filter
MAXIMUM18,855.90sesuai filter
REPORT RESULT

Data Sensor

19/10/2026 — 19/10/2026 EXPORT CSV
NOTANGGALWAKTUDEVICECHANNELSENSORVALUEUNIT
73601 19/10/2026 13:12:00 Mainboard Lantai 3MB-L3-01 L3-HFT-01 Heat Flow 1 29.65 W/m²
73602 19/10/2026 13:12:00 Mainboard Lantai 3MB-L3-01 L3-AI-04 Analog Input 4 3.12 V
73603 19/10/2026 13:12:00 Mainboard Lantai 3MB-L3-01 L3-RAD-01 Radiation 1 19.00 W/m²
73604 19/10/2026 13:12:00 Mainboard Lantai 3MB-L3-01 L3-LUX-01 Illuminance / LUX 1 776.70 lux
73605 19/10/2026 13:12:00 Mainboard Lantai 3MB-L3-01 L3-SHT-02-T SHT20 2 Temperature 28.30 °C
73606 19/10/2026 13:12:00 Mainboard Lantai 3MB-L3-01 L3-HFT-02 Heat Flow 2 34.48 W/m²
73607 19/10/2026 13:12:00 Mainboard Lantai 3MB-L3-01 L3-AI-05 Analog Input 5 3.12 V
73608 19/10/2026 13:12:00 Mainboard Lantai 3MB-L3-01 L3-RAD-02 Radiation 2 25.00 W/m²
73609 19/10/2026 13:12:00 Mainboard Lantai 3MB-L3-01 L3-AI-01 Analog Input 1 3.12 V
73610 19/10/2026 13:12:00 Mainboard Lantai 3MB-L3-01 L3-LUX-02 Illuminance / LUX 2 1,117.30 lux
73611 19/10/2026 13:12:00 Mainboard Lantai 3MB-L3-01 L3-SHT-02-RH SHT20 2 Humidity 54.28 %RH
73612 19/10/2026 13:12:00 Mainboard Lantai 3MB-L3-01 L3-BGT-01 Black Globe Temperature 1 33.84 °C
73613 19/10/2026 13:12:00 Mainboard Lantai 3MB-L3-01 L3-AI-06 Analog Input 6 3.12 V
73614 19/10/2026 13:12:00 Mainboard Lantai 3MB-L3-01 L3-ST-01 Surface Temperature 1 38.86 °C
73615 19/10/2026 13:12:00 Mainboard Lantai 3MB-L3-01 L3-AI-02 Analog Input 2 3.12 V
73616 19/10/2026 13:12:00 Mainboard Lantai 3MB-L3-01 L3-LUX-03 Illuminance / LUX 3 1,022.60 lux
73617 19/10/2026 13:12:00 Mainboard Lantai 3MB-L3-01 L3-SHT-03-T SHT20 3 Temperature 28.70 °C
73618 19/10/2026 13:12:00 Sensor Mainboard L3PWR-L3-01 PZEM-L3-01-VOLT PZEM L3-01 Voltage 223.90 V
73619 19/10/2026 13:12:00 Actuator ModuleACT-MOD-01 ENC-05 Rotary Encoder 5 89.00 %
73620 19/10/2026 13:12:00 Mainboard Lantai 3MB-L3-01 L3-BGT-02 Black Globe Temperature 2 31.84 °C
73621 19/10/2026 13:12:00 Remote ACAC-REMOTE-01 AC-SETPOINT AC Set Temperature 26.00 °C
73622 19/10/2026 13:12:00 Sensor Lampu L3PWR-L3-02 PZEM-L3-02-VOLT PZEM L3-02 Voltage 223.60 V
73623 19/10/2026 13:12:00 Sensor Lampu L5PWR-L5-02 PZEM-L5-02-PF PZEM L5-02 Power Factor 1.00
73624 19/10/2026 13:12:00 Sensor Mainboard L5PWR-L5-01 PZEM-L5-01-POWER PZEM L5-01 Active Power 9.50 W
73625 19/10/2026 13:12:00 Actuator ModuleACT-MOD-01 MOTOR-04 Motor Status 4 0.00 state
73626 19/10/2026 13:12:00 Actuator ModuleACT-MOD-01 ENC-07 Rotary Encoder 7 89.00 %
73627 19/10/2026 13:12:00 Actuator ModuleACT-MOD-01 ENC-02 Rotary Encoder 2 44.00 %
73628 19/10/2026 13:12:00 Sensor Mainboard L5PWR-L5-01 PZEM-L5-01-PF PZEM L5-01 Power Factor 0.45
73629 19/10/2026 13:12:00 Sensor Lampu L5PWR-L5-02 PZEM-L5-02-VOLT PZEM L5-02 Voltage 219.20 V
73630 19/10/2026 13:12:00 Sensor Mainboard L3PWR-L3-01 PZEM-L3-01-PF PZEM L3-01 Power Factor 0.46
73631 19/10/2026 13:12:00 Actuator ModuleACT-MOD-01 MOTOR-06 Motor Status 6 0.00 state
73632 19/10/2026 13:12:00 Sensor Mainboard L5PWR-L5-01 PZEM-L5-01-VOLT PZEM L5-01 Voltage 219.20 V
73633 19/10/2026 13:12:00 Actuator ModuleACT-MOD-01 MOTOR-01 Motor Status 1 0.00 state
73634 19/10/2026 13:12:00 Sensor Pendingin RuanganPWR-L5-04 PZEM-L5-04-FREQ PZEM L5-04 Frequency 50.00 Hz
73635 19/10/2026 13:12:00 Sensor Pendingin RuanganPWR-L5-04 PZEM-L5-04-VOLT PZEM L5-04 Voltage 218.90 V
73636 19/10/2026 13:12:00 Sensor Mainboard L3PWR-L3-01 PZEM-L3-01-ENERGY PZEM L3-01 Energy 11.02 kWh
73637 19/10/2026 13:12:00 Actuator ModuleACT-MOD-01 ENC-04 Rotary Encoder 4 44.50 %
73638 19/10/2026 13:12:00 Sensor Pendingin RuanganPWR-L5-04 PZEM-L5-04-POWER PZEM L5-04 Active Power 0.00 W
73639 19/10/2026 13:12:00 Sensor Lampu L5PWR-L5-02 PZEM-L5-02-CURR PZEM L5-02 Current 0.00 A
73640 19/10/2026 13:12:00 Sensor Actuator L5PWR-L5-03 PZEM-L5-03-CURR PZEM L5-03 Current 0.00 A
73641 19/10/2026 13:12:00 Sensor Mainboard L3PWR-L3-01 PZEM-L3-01-CURR PZEM L3-01 Current 0.10 A
73642 19/10/2026 13:12:00 Weather Station ModuleWS-MOD-01 WS-TEMP Suhu Udara 30.00 °C
73643 19/10/2026 13:12:00 Sensor Mainboard L5PWR-L5-01 PZEM-L5-01-ENERGY PZEM L5-01 Energy 9.89 kWh
73644 19/10/2026 13:12:00 Weather Station ModuleWS-MOD-01 WS-RH Kelembapan Udara 51.60 %RH
73645 19/10/2026 13:12:00 Remote ACAC-REMOTE-01 AC-MODE AC Operating Mode 1.00 code
73646 19/10/2026 13:12:00 Weather Station ModuleWS-MOD-01 WS-PRES Tekanan Udara 907.00 hPa
73647 19/10/2026 13:12:00 Weather Station ModuleWS-MOD-01 WS-DIR Arah Angin 210.80 °
73648 19/10/2026 13:12:00 Weather Station ModuleWS-MOD-01 WS-WIND Kecepatan Angin 6.86 m/s
73649 19/10/2026 13:12:00 Actuator ModuleACT-MOD-01 MOTOR-08 Motor Status 8 0.00 state
73650 19/10/2026 13:12:00 Remote ACAC-REMOTE-01 AC-POWER AC Power State 1.00 state
73651 19/10/2026 13:12:00 Mainboard Lantai 5MB-L5-01 L5-ST-01 Surface Temperature 1 31.07 °C
73652 19/10/2026 13:12:00 Mainboard Lantai 5MB-L5-01 L5-AI-02 Analog Input 2 3.05 V
73653 19/10/2026 13:12:00 Mainboard Lantai 5MB-L5-01 L5-LUX-03 Illuminance / LUX 3 435.90 lux
73654 19/10/2026 13:12:00 Mainboard Lantai 5MB-L5-01 L5-SHT-03-T SHT20 3 Temperature 26.80 °C
73655 19/10/2026 13:12:00 Mainboard Lantai 5MB-L5-01 L5-BGT-02 Black Globe Temperature 2 28.25 °C
73656 19/10/2026 13:12:00 Mainboard Lantai 5MB-L5-01 L5-SHT-01-T SHT20 1 Temperature 28.40 °C
73657 19/10/2026 13:12:00 Actuator ModuleACT-MOD-01 MOTOR-03 Motor Status 3 0.00 state
73658 19/10/2026 13:12:00 Mainboard Lantai 5MB-L5-01 L5-ST-02 Surface Temperature 2 32.73 °C
73659 19/10/2026 13:12:00 Mainboard Lantai 5MB-L5-01 L5-AI-03 Analog Input 3 3.05 V
73660 19/10/2026 13:12:00 Mainboard Lantai 5MB-L5-01 L5-LUX-04 Illuminance / LUX 4 216.50 lux
73661 19/10/2026 13:12:00 Mainboard Lantai 5MB-L5-01 L5-SHT-03-RH SHT20 3 Humidity 56.57 %RH
73662 19/10/2026 13:12:00 Sensor Lampu L3PWR-L3-02 PZEM-L3-02-PF PZEM L3-02 Power Factor 0.00
73663 19/10/2026 13:12:00 Mainboard Lantai 5MB-L5-01 L5-BGT-03 Black Globe Temperature 3 29.02 °C
73664 19/10/2026 13:12:00 Mainboard Lantai 5MB-L5-01 L5-SHT-01-RH SHT20 1 Humidity 53.78 %RH
73665 19/10/2026 13:12:00 Mainboard Lantai 5MB-L5-01 L5-HFT-01 Heat Flow 1 10.52 W/m²
73666 19/10/2026 13:12:00 Sensor Actuator L5PWR-L5-03 PZEM-L5-03-POWER PZEM L5-03 Active Power 0.00 W
73667 19/10/2026 13:12:00 Mainboard Lantai 5MB-L5-01 L5-AI-04 Analog Input 4 3.05 V
73668 19/10/2026 13:12:00 Mainboard Lantai 5MB-L5-01 L5-LUX-05 Illuminance / LUX 5 1,591.00 lux
73669 19/10/2026 13:12:00 Mainboard Lantai 5MB-L5-01 L5-RAD-01 Radiation 1 8.00 W/m²
73670 19/10/2026 13:12:00 Mainboard Lantai 3MB-L3-01 L3-LUX-06 Illuminance / LUX 6 3,698.80 lux
73671 19/10/2026 13:12:00 Mainboard Lantai 5MB-L5-01 L5-LUX-01 Illuminance / LUX 1 248.90 lux
73672 19/10/2026 13:12:00 Mainboard Lantai 5MB-L5-01 L5-SHT-02-T SHT20 2 Temperature 27.60 °C
73673 19/10/2026 13:12:00 Mainboard Lantai 5MB-L5-01 L5-HFT-02 Heat Flow 2 3.28 W/m²
73674 19/10/2026 13:12:00 Mainboard Lantai 5MB-L5-01 L5-AI-05 Analog Input 5 3.05 V
73675 19/10/2026 13:12:00 Mainboard Lantai 5MB-L5-01 L5-LUX-06 Illuminance / LUX 6 0.00 lux
73676 19/10/2026 13:12:00 Mainboard Lantai 5MB-L5-01 L5-RAD-02 Radiation 2 9.00 W/m²
73677 19/10/2026 13:12:00 Mainboard Lantai 5MB-L5-01 L5-AI-01 Analog Input 1 3.05 V
73678 19/10/2026 13:12:00 Mainboard Lantai 5MB-L5-01 L5-LUX-02 Illuminance / LUX 2 1,178.70 lux
73679 19/10/2026 13:12:00 Mainboard Lantai 5MB-L5-01 L5-SHT-02-RH SHT20 2 Humidity 54.75 %RH
73680 19/10/2026 13:12:00 Mainboard Lantai 5MB-L5-01 L5-BGT-01 Black Globe Temperature 1 28.07 °C
73681 19/10/2026 13:12:00 Mainboard Lantai 5MB-L5-01 L5-AI-06 Analog Input 6 3.05 V
73682 19/10/2026 13:12:00 Actuator ModuleACT-MOD-01 ENC-06 Rotary Encoder 6 89.00 %
73683 19/10/2026 13:12:00 Sensor Lampu L5PWR-L5-02 PZEM-L5-02-POWER PZEM L5-02 Active Power 0.70 W
73684 19/10/2026 13:12:00 Actuator ModuleACT-MOD-01 ENC-01 Rotary Encoder 1 43.50 %
73685 19/10/2026 13:12:00 Sensor Lampu L3PWR-L3-02 PZEM-L3-02-FREQ PZEM L3-02 Frequency 50.00 Hz
73686 19/10/2026 13:12:00 Sensor Actuator L5PWR-L5-03 PZEM-L5-03-ENERGY PZEM L5-03 Energy 0.00 kWh
73687 19/10/2026 13:12:00 Sensor Lampu L5PWR-L5-02 PZEM-L5-02-ENERGY PZEM L5-02 Energy 11.38 kWh
73688 19/10/2026 13:12:00 Actuator ModuleACT-MOD-01 MOTOR-05 Motor Status 5 0.00 state
73689 19/10/2026 13:12:00 Sensor Mainboard L5PWR-L5-01 PZEM-L5-01-CURR PZEM L5-01 Current 0.10 A
73690 19/10/2026 13:12:00 Sensor Lampu L3PWR-L3-02 PZEM-L3-02-ENERGY PZEM L3-02 Energy 0.93 kWh
73691 19/10/2026 13:12:00 Mainboard Lantai 3MB-L3-01 L3-LUX-05 Illuminance / LUX 5 2,503.10 lux
73692 19/10/2026 13:12:00 Actuator ModuleACT-MOD-01 ENC-08 Rotary Encoder 8 89.00 %
73693 19/10/2026 13:12:00 Actuator ModuleACT-MOD-01 ENC-03 Rotary Encoder 3 45.50 %
73694 19/10/2026 13:12:00 Sensor Actuator L5PWR-L5-03 PZEM-L5-03-FREQ PZEM L5-03 Frequency 0.00 Hz
73695 19/10/2026 13:12:00 Sensor Lampu L3PWR-L3-02 PZEM-L3-02-POWER PZEM L3-02 Active Power 0.00 W
73696 19/10/2026 13:11:00 Sensor Lampu L3PWR-L3-02 PZEM-L3-02-FREQ PZEM L3-02 Frequency 50.00 Hz
73697 19/10/2026 13:11:00 Sensor Actuator L5PWR-L5-03 PZEM-L5-03-ENERGY PZEM L5-03 Energy 0.00 kWh
73698 19/10/2026 13:11:00 Sensor Lampu L5PWR-L5-02 PZEM-L5-02-ENERGY PZEM L5-02 Energy 11.38 kWh
73699 19/10/2026 13:11:00 Actuator ModuleACT-MOD-01 MOTOR-05 Motor Status 5 0.00 state
73700 19/10/2026 13:11:00 Sensor Mainboard L5PWR-L5-01 PZEM-L5-01-CURR PZEM L5-01 Current 0.10 A
Menampilkan maksimal 100 data per halaman