DEVICE NETWORK
Gateway Status
11 gateway ditampilkan · realtime ~1s · history 60s
Weather
WS-MOD-01
OFFLINE
Actuator
ACT-MOD-01
OFFLINE
Mainboard L3
MB-L3-01
ONLINE
Mainboard L5
MB-L5-01
OFFLINE
Remote AC
AC-REMOTE-01
OFFLINE
Sensor Mainboard L3
PWR-L3-01
OFFLINE
Sensor Lampu L3
PWR-L3-02
ONLINE
Sensor Mainboard L5
PWR-L5-01
OFFLINE
Sensor Lampu L5
PWR-L5-02
OFFLINE
Sensor Actuator L5
PWR-L5-03
OFFLINE
Sensor Pendingin Ruangan
PWR-L5-04
OFFLINE
REPORT FILTER
DATABASE HISTORY
Periode & Sensor
REPORT RESULT
Data Sensor
21/11/2026 — 21/11/2026
EXPORT CSV
| NO | TANGGAL | WAKTU | DEVICE | CHANNEL | SENSOR | VALUE | UNIT |
|---|---|---|---|---|---|---|---|
| 39201 | 21/11/2026 | 18:21:00 | Mainboard Lantai 3MB-L3-01 | L3-AI-03 | Analog Input 3 | 3.12 | V |
| 39202 | 21/11/2026 | 18:21:00 | Actuator ModuleACT-MOD-01 | ENC-06 | Rotary Encoder 6 | 89.00 | % |
| 39203 | 21/11/2026 | 18:21:00 | Mainboard Lantai 5MB-L5-01 | L5-LUX-03 | Illuminance / LUX 3 | 0.10 | lux |
| 39204 | 21/11/2026 | 18:21:00 | Mainboard Lantai 5MB-L5-01 | L5-SHT-03-T | SHT20 3 Temperature | 25.70 | °C |
| 39205 | 21/11/2026 | 18:21:00 | Mainboard Lantai 3MB-L3-01 | L3-LUX-04 | Illuminance / LUX 4 | 0.20 | lux |
| 39206 | 21/11/2026 | 18:21:00 | Mainboard Lantai 3MB-L3-01 | L3-SHT-03-RH | SHT20 3 Humidity | 79.81 | %RH |
| 39207 | 21/11/2026 | 18:21:00 | Remote ACAC-REMOTE-01 | AC-FAN | AC Fan Speed | 0.00 | code |
| 39208 | 21/11/2026 | 18:21:00 | Mainboard Lantai 5MB-L5-01 | L5-BGT-02 | Black Globe Temperature 2 | 26.34 | °C |
| 39209 | 21/11/2026 | 18:21:00 | Mainboard Lantai 5MB-L5-01 | L5-SHT-01-T | SHT20 1 Temperature | 25.80 | °C |
| 39210 | 21/11/2026 | 18:21:00 | Mainboard Lantai 3MB-L3-01 | L3-BGT-03 | Black Globe Temperature 3 | 28.48 | °C |
| 39211 | 21/11/2026 | 18:21:00 | Mainboard Lantai 3MB-L3-01 | L3-SHT-01-RH | SHT20 1 Humidity | 80.04 | %RH |
| 39212 | 21/11/2026 | 18:21:00 | Mainboard Lantai 5MB-L5-01 | L5-RAD-04 | Radiasi Luar Utara | 1.00 | W/m² |
| 39213 | 21/11/2026 | 18:21:00 | Mainboard Lantai 5MB-L5-01 | L5-ST-02 | Surface Temperature 2 | 24.70 | °C |
| 39214 | 21/11/2026 | 18:21:00 | Mainboard Lantai 5MB-L5-01 | L5-AI-03 | Analog Input 3 | 3.05 | V |
| 39215 | 21/11/2026 | 18:21:00 | Mainboard Lantai 3MB-L3-01 | L3-HFT-01 | Heat Flow 1 | -8.52 | W/m² |
| 39216 | 21/11/2026 | 18:21:00 | Mainboard Lantai 3MB-L3-01 | L3-AI-04 | Analog Input 4 | 3.12 | V |
| 39217 | 21/11/2026 | 18:21:00 | Mainboard Lantai 5MB-L5-01 | L5-LUX-04 | Illuminance / LUX 4 | 0.00 | lux |
| 39218 | 21/11/2026 | 18:21:00 | Mainboard Lantai 5MB-L5-01 | L5-SHT-03-RH | SHT20 3 Humidity | 73.89 | %RH |
| 39219 | 21/11/2026 | 18:21:00 | Mainboard Lantai 3MB-L3-01 | L3-LUX-05 | Illuminance / LUX 5 | 0.40 | lux |
| 39220 | 21/11/2026 | 18:21:00 | Mainboard Lantai 3MB-L3-01 | L3-RAD-01 | Radiation 1 | 1.00 | W/m² |
| 39221 | 21/11/2026 | 18:21:00 | Mainboard Lantai 5MB-L5-01 | L5-BGT-03 | Black Globe Temperature 3 | 26.16 | °C |
| 39222 | 21/11/2026 | 18:21:00 | Mainboard Lantai 5MB-L5-01 | L5-SHT-01-RH | SHT20 1 Humidity | 73.89 | %RH |
| 39223 | 21/11/2026 | 18:21:00 | Mainboard Lantai 3MB-L3-01 | L3-LUX-01 | Illuminance / LUX 1 | 0.20 | lux |
| 39224 | 21/11/2026 | 18:21:00 | Mainboard Lantai 3MB-L3-01 | L3-SHT-02-T | SHT20 2 Temperature | 25.30 | °C |
| 39225 | 21/11/2026 | 18:21:00 | Mainboard Lantai 5MB-L5-01 | L5-HFT-01 | Heat Flow 1 | -34.22 | W/m² |
| 39226 | 21/11/2026 | 18:21:00 | Mainboard Lantai 5MB-L5-01 | L5-AI-04 | Analog Input 4 | 3.05 | V |
| 39227 | 21/11/2026 | 18:21:00 | Mainboard Lantai 3MB-L3-01 | L3-HFT-02 | Heat Flow 2 | -12.26 | W/m² |
| 39228 | 21/11/2026 | 18:21:00 | Mainboard Lantai 3MB-L3-01 | L3-AI-05 | Analog Input 5 | 3.12 | V |
| 39229 | 21/11/2026 | 18:21:00 | Mainboard Lantai 5MB-L5-01 | L5-LUX-05 | Illuminance / LUX 5 | 0.10 | lux |
| 39230 | 21/11/2026 | 18:21:00 | Mainboard Lantai 5MB-L5-01 | L5-RAD-01 | Radiation 1 | 1.00 | W/m² |
| 39231 | 21/11/2026 | 18:21:00 | Mainboard Lantai 3MB-L3-01 | L3-LUX-06 | Illuminance / LUX 6 | 0.40 | lux |
| 39232 | 21/11/2026 | 18:21:00 | Mainboard Lantai 3MB-L3-01 | L3-RAD-02 | Radiation 2 | 0.00 | W/m² |
| 39233 | 21/11/2026 | 18:21:00 | Mainboard Lantai 3MB-L3-01 | L3-AI-01 | Analog Input 1 | 3.12 | V |
| 39234 | 21/11/2026 | 18:21:00 | Mainboard Lantai 5MB-L5-01 | L5-LUX-01 | Illuminance / LUX 1 | 0.00 | lux |
| 39235 | 21/11/2026 | 18:21:00 | Mainboard Lantai 5MB-L5-01 | L5-SHT-02-T | SHT20 2 Temperature | 26.00 | °C |
| 39236 | 21/11/2026 | 18:21:00 | Mainboard Lantai 3MB-L3-01 | L3-LUX-02 | Illuminance / LUX 2 | 0.30 | lux |
| 39237 | 21/11/2026 | 18:21:00 | Mainboard Lantai 3MB-L3-01 | L3-SHT-02-RH | SHT20 2 Humidity | 78.89 | %RH |
| 39238 | 21/11/2026 | 18:21:00 | Mainboard Lantai 5MB-L5-01 | L5-HFT-02 | Heat Flow 2 | -30.32 | W/m² |
| 39239 | 21/11/2026 | 18:21:00 | Mainboard Lantai 5MB-L5-01 | L5-AI-05 | Analog Input 5 | 3.05 | V |
| 39240 | 21/11/2026 | 18:21:00 | Mainboard Lantai 3MB-L3-01 | L3-BGT-01 | Black Globe Temperature 1 | 29.84 | °C |
| 39241 | 21/11/2026 | 18:21:00 | Mainboard Lantai 3MB-L3-01 | L3-AI-06 | Analog Input 6 | 3.12 | V |
| 39242 | 21/11/2026 | 18:21:00 | Mainboard Lantai 5MB-L5-01 | L5-LUX-06 | Illuminance / LUX 6 | 0.00 | lux |
| 39243 | 21/11/2026 | 18:21:00 | Mainboard Lantai 5MB-L5-01 | L5-RAD-02 | Radiation 2 | 1.00 | W/m² |
| 39244 | 21/11/2026 | 18:21:00 | Mainboard Lantai 5MB-L5-01 | L5-AI-01 | Analog Input 1 | 3.05 | V |
| 39245 | 21/11/2026 | 18:21:00 | Mainboard Lantai 3MB-L3-01 | L3-ST-01 | Surface Temperature 1 | 30.22 | °C |
| 39246 | 21/11/2026 | 18:21:00 | Mainboard Lantai 3MB-L3-01 | L3-AI-02 | Analog Input 2 | 3.12 | V |
| 39247 | 21/11/2026 | 18:21:00 | Actuator ModuleACT-MOD-01 | MOTOR-01 | Motor Status 1 | 0.00 | state |
| 39248 | 21/11/2026 | 18:21:00 | Actuator ModuleACT-MOD-01 | MOTOR-04 | Motor Status 4 | 0.00 | state |
| 39249 | 21/11/2026 | 18:21:00 | Sensor Pendingin RuanganPWR-L5-04 | PZEM-L5-04-FREQ | PZEM L5-04 Frequency | 50.00 | Hz |
| 39250 | 21/11/2026 | 18:21:00 | Actuator ModuleACT-MOD-01 | MOTOR-07 | Motor Status 7 | 0.00 | state |
| 39251 | 21/11/2026 | 18:21:00 | Sensor Lampu L5PWR-L5-02 | PZEM-L5-02-POWER | PZEM L5-02 Active Power | 0.00 | W |
| 39252 | 21/11/2026 | 18:21:00 | Sensor Mainboard L5PWR-L5-01 | PZEM-L5-01-VOLT | PZEM L5-01 Voltage | 221.00 | V |
| 39253 | 21/11/2026 | 18:21:00 | Remote ACAC-REMOTE-01 | AC-MODE | AC Operating Mode | 1.00 | code |
| 39254 | 21/11/2026 | 18:21:00 | Sensor Lampu L5PWR-L5-02 | PZEM-L5-02-CURR | PZEM L5-02 Current | 0.00 | A |
| 39255 | 21/11/2026 | 18:21:00 | Sensor Pendingin RuanganPWR-L5-04 | PZEM-L5-04-PF | PZEM L5-04 Power Factor | 0.03 | |
| 39256 | 21/11/2026 | 18:21:00 | Sensor Lampu L3PWR-L3-02 | PZEM-L3-02-ENERGY | PZEM L3-02 Energy | 1.01 | kWh |
| 39257 | 21/11/2026 | 18:21:00 | Sensor Lampu L3PWR-L3-02 | PZEM-L3-02-FREQ | PZEM L3-02 Frequency | 50.00 | Hz |
| 39258 | 21/11/2026 | 18:21:00 | Sensor Mainboard L5PWR-L5-01 | PZEM-L5-01-POWER | PZEM L5-01 Active Power | 9.50 | W |
| 39259 | 21/11/2026 | 18:21:00 | Sensor Lampu L3PWR-L3-02 | PZEM-L3-02-VOLT | PZEM L3-02 Voltage | 220.70 | V |
| 39260 | 21/11/2026 | 18:21:00 | Sensor Lampu L3PWR-L3-02 | PZEM-L3-02-PF | PZEM L3-02 Power Factor | 0.00 | |
| 39261 | 21/11/2026 | 18:21:00 | Sensor Lampu L3PWR-L3-02 | PZEM-L3-02-CURR | PZEM L3-02 Current | 0.00 | A |
| 39262 | 21/11/2026 | 18:21:00 | Sensor Lampu L3PWR-L3-02 | PZEM-L3-02-POWER | PZEM L3-02 Active Power | 0.00 | W |
| 39263 | 21/11/2026 | 18:21:00 | Actuator ModuleACT-MOD-01 | ENC-01 | Rotary Encoder 1 | 63.00 | % |
| 39264 | 21/11/2026 | 18:21:00 | Sensor Lampu L5PWR-L5-02 | PZEM-L5-02-VOLT | PZEM L5-02 Voltage | 221.00 | V |
| 39265 | 21/11/2026 | 18:21:00 | Actuator ModuleACT-MOD-01 | ENC-04 | Rotary Encoder 4 | 116.50 | % |
| 39266 | 21/11/2026 | 18:21:00 | Sensor Daya AC L3PWR-L3-03 | PZEM-L3-03-POWER | PZEM L3-03 Active Power | 9.90 | W |
| 39267 | 21/11/2026 | 18:21:00 | Sensor Daya AC L3PWR-L3-03 | PZEM-L3-03-ENERGY | PZEM L3-03 Energy | 15.52 | kWh |
| 39268 | 21/11/2026 | 18:21:00 | Actuator ModuleACT-MOD-01 | ENC-07 | Rotary Encoder 7 | 89.00 | % |
| 39269 | 21/11/2026 | 18:21:00 | Sensor Daya AC L3PWR-L3-03 | PZEM-L3-03-FREQ | PZEM L3-03 Frequency | 49.90 | Hz |
| 39270 | 21/11/2026 | 18:21:00 | Sensor Daya AC L3PWR-L3-03 | PZEM-L3-03-PF | PZEM L3-03 Power Factor | 0.40 | |
| 39271 | 21/11/2026 | 18:21:00 | Sensor Daya AC L3PWR-L3-03 | PZEM-L3-03-CURR | PZEM L3-03 Current | 0.11 | A |
| 39272 | 21/11/2026 | 18:21:00 | Actuator ModuleACT-MOD-01 | MOTOR-02 | Motor Status 2 | 0.00 | state |
| 39273 | 21/11/2026 | 18:21:00 | Remote ACAC-REMOTE-01 | AC-SETPOINT | AC Set Temperature | 26.00 | °C |
| 39274 | 21/11/2026 | 18:21:00 | Sensor Mainboard L5PWR-L5-01 | PZEM-L5-01-FREQ | PZEM L5-01 Frequency | 50.00 | Hz |
| 39275 | 21/11/2026 | 18:21:00 | Actuator ModuleACT-MOD-01 | MOTOR-05 | Motor Status 5 | 0.00 | state |
| 39276 | 21/11/2026 | 18:21:00 | Actuator ModuleACT-MOD-01 | MOTOR-08 | Motor Status 8 | 0.00 | state |
| 39277 | 21/11/2026 | 18:20:00 | Sensor Lampu L3PWR-L3-02 | PZEM-L3-02-ENERGY | PZEM L3-02 Energy | 1.01 | kWh |
| 39278 | 21/11/2026 | 18:20:00 | Sensor Lampu L3PWR-L3-02 | PZEM-L3-02-FREQ | PZEM L3-02 Frequency | 50.00 | Hz |
| 39279 | 21/11/2026 | 18:20:00 | Sensor Mainboard L5PWR-L5-01 | PZEM-L5-01-POWER | PZEM L5-01 Active Power | 9.60 | W |
| 39280 | 21/11/2026 | 18:20:00 | Sensor Lampu L3PWR-L3-02 | PZEM-L3-02-VOLT | PZEM L3-02 Voltage | 220.80 | V |
| 39281 | 21/11/2026 | 18:20:00 | Sensor Lampu L3PWR-L3-02 | PZEM-L3-02-PF | PZEM L3-02 Power Factor | 0.00 | |
| 39282 | 21/11/2026 | 18:20:00 | Sensor Lampu L3PWR-L3-02 | PZEM-L3-02-CURR | PZEM L3-02 Current | 0.00 | A |
| 39283 | 21/11/2026 | 18:20:00 | Sensor Lampu L3PWR-L3-02 | PZEM-L3-02-POWER | PZEM L3-02 Active Power | 0.00 | W |
| 39284 | 21/11/2026 | 18:20:00 | Actuator ModuleACT-MOD-01 | ENC-01 | Rotary Encoder 1 | 63.00 | % |
| 39285 | 21/11/2026 | 18:20:00 | Sensor Lampu L5PWR-L5-02 | PZEM-L5-02-VOLT | PZEM L5-02 Voltage | 221.00 | V |
| 39286 | 21/11/2026 | 18:20:00 | Actuator ModuleACT-MOD-01 | ENC-04 | Rotary Encoder 4 | 116.50 | % |
| 39287 | 21/11/2026 | 18:20:00 | Sensor Daya AC L3PWR-L3-03 | PZEM-L3-03-POWER | PZEM L3-03 Active Power | 9.90 | W |
| 39288 | 21/11/2026 | 18:20:00 | Sensor Daya AC L3PWR-L3-03 | PZEM-L3-03-ENERGY | PZEM L3-03 Energy | 15.52 | kWh |
| 39289 | 21/11/2026 | 18:20:00 | Actuator ModuleACT-MOD-01 | ENC-07 | Rotary Encoder 7 | 89.00 | % |
| 39290 | 21/11/2026 | 18:20:00 | Sensor Daya AC L3PWR-L3-03 | PZEM-L3-03-FREQ | PZEM L3-03 Frequency | 49.90 | Hz |
| 39291 | 21/11/2026 | 18:20:00 | Sensor Daya AC L3PWR-L3-03 | PZEM-L3-03-PF | PZEM L3-03 Power Factor | 0.40 | |
| 39292 | 21/11/2026 | 18:20:00 | Sensor Daya AC L3PWR-L3-03 | PZEM-L3-03-CURR | PZEM L3-03 Current | 0.11 | A |
| 39293 | 21/11/2026 | 18:20:00 | Actuator ModuleACT-MOD-01 | MOTOR-02 | Motor Status 2 | 0.00 | state |
| 39294 | 21/11/2026 | 18:20:00 | Remote ACAC-REMOTE-01 | AC-SETPOINT | AC Set Temperature | 26.00 | °C |
| 39295 | 21/11/2026 | 18:20:00 | Sensor Mainboard L5PWR-L5-01 | PZEM-L5-01-FREQ | PZEM L5-01 Frequency | 50.00 | Hz |
| 39296 | 21/11/2026 | 18:20:00 | Actuator ModuleACT-MOD-01 | MOTOR-05 | Motor Status 5 | 0.00 | state |
| 39297 | 21/11/2026 | 18:20:00 | Actuator ModuleACT-MOD-01 | MOTOR-08 | Motor Status 8 | 0.00 | state |
| 39298 | 21/11/2026 | 18:20:00 | Sensor Actuator L5PWR-L5-03 | PZEM-L5-03-PF | PZEM L5-03 Power Factor | 0.45 | |
| 39299 | 21/11/2026 | 18:20:00 | Weather Station ModuleWS-MOD-01 | WS-TEMP | Suhu Udara | 21.50 | °C |
| 39300 | 21/11/2026 | 18:20:00 | Weather Station ModuleWS-MOD-01 | WS-RH | Kelembapan Udara | 99.70 | %RH |
Menampilkan maksimal 100 data per halaman